Neutron Imaging for Laser Selective Melting Inconel Hardware with Internal Passages Dr. Terri L. Tramel (MSFC), Joseph K. Norwood (MSFC), Dr. Hassina Bilheux (ORNL) Specifications Wavelength 1 .8 < X < 6 A | Wavelength resolution A)A-10% rtghtest spatial resolution 50 microns (FOV: 4x4 cnf) and 1 00 microns (FOV: 6x6cm^ Sample- to-detector distance 5m Detector CCDs Detector chp size 2048x2048 pixels Detector resolution 5.2 x 5.2 (FOV: 4x4 cm-') and 13.4 x 13.4 (FOV: 6x6 cm 2 ) microns* pixels Detector frame rate 1 fps (1 to 5 min required per image) Future Work: Generate highest resolution (5 um) 3D reconstruction and overlay the reconstruction onto build model for absolute metrology comparison 0.4” block stacked on 0.6” block (Inconel 718) in the CG-1D Neutron Imaging Prototype Facility at Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR)